From Consultation to Preoperative Design: How Aesthetic Clinics Use the 3D Plastic Surgery System

Interface of the 3D Digital Plastic Surgery System

The real value of a 3D device is not that it scans a model, but what happens once the model enters the consultation: can it be analysed, can it produce a report, can it be used for design, can it be compared.

1. Capture: standardize the data first

The same patient, the same device, the same working distance and the same posture are the preconditions for any later comparison. Floor-standing devices such as the MVS-P6, MVS-800 and MVS-C6 complete a full scan in under 2 s; the MVS-M6 and MVS-M2N in under 9 s; the MVS-N1 is used intraoperatively; the ZETTA completes a full scan in under 25 s.

Before capture, deal with hair, makeup, reflections and occlusion. The hairline, the preauricular area and the mandibular border are common gaps; after capture, check mesh completeness in the software before moving on to analysis.

2. Analysis: how to use 60 facial metrics

The 3D Digital Plastic Surgery System provides 60 facial metrics covering proportions, angles and symmetry, and a curvature map for skeletal and soft-tissue analysis. Many metrics does not mean all of them should be explained to the patient; in a consultation it is better to choose 3-5 around the chief complaint.

For the nose, for example, discuss the nasofrontal angle, the nasolabial angle and the dorsum curve; for the midface, the midfacial proportions and volume distribution; for the contour, left-right differences and continuity of the mandibular border. Numbers give a description a reference point; they do not replace judgement.

Facial analysis interface of the 3D Digital Plastic Surgery System
Curvature map for skeletal and soft-tissue analysis

3. Reports: turning what is on screen into something to take away

A report is the carrier that fixes the content of a consultation. The system supports report output and printing, and can include model screenshots, metric values and notes. A report should state the capture date, device model and metric definitions so it can be compared at follow-up.

A report is communication material, not a diagnostic conclusion. Judgements about indications, risks and treatment plans remain with the clinician.

4. Design: aesthetic design and injection simulation

Adjusting a preview on the 3D model turns "what if this point were slightly higher" into a visible change in form. Injection simulation is used to observe contour change after volume adjustment; aesthetic design supports plan discussion for the nose, chin, midface and other areas. The nasal design workflow on the MVS-M6, MVS-M2N and MVS-M6HD follows the same logic: capture first, then design, then compare.

Design results are used for communication and plan discussion, not as a commitment about post-treatment results. This should be stated clearly during the consultation.

Workflow demonstration from capture to design to comparison

5. Comparison and archiving: two dedicated pages

For how to use the color, cross-section and multi-open comparison views, and what photos, 2D and 3D can each show, see Pre- and post-treatment comparison: what photos, 2D and 3D can each show. The point to stress here is the precondition: the same device, the same distance and the same expression, otherwise the numbers are not comparable.

For which fields a record should keep, how to name files and how to re-capture at follow-up, see 3D scan data in records and follow-up. The bottom line is to keep the raw model, the analysis results, the report and the design version together: save screenshots only and the data can no longer be analysed.

StepOutputCommon issues
Capture3D model + textureHair occlusion, makeup reflections, posture drift
Analysis60 metrics, curvature mapA pile of metrics with no link to the chief complaint
ReportPDF / printoutMissing capture conditions and metric definitions
DesignSimulation planTreating a simulation as a commitment about results
ComparisonColor / cross-section / multi-open viewsInconsistent protocol before and after
ArchivingCase recordKeeping screenshots but not raw data

Related pages: 3D Digital Plastic Surgery System, MVS-P6, MVS-800, MVS-C6, MVS-M6, MVS-M2N, MVS-N1, ZETTA.

This article describes software functions and workflows and is not medical advice; specific metrics, modules and report layouts are subject to the software version and contract.